Ore Tracking RFID Tagging Specification (DWG)
The Ore Tracking RFID Tagging Specification (DWG) is a technical drawing document that defines the physical, electrical, and data-encoding requirements for RFID tags used to uniquely identify and track ore batches throughout mining and metallurgical processing workflows. It specifies tag mounting locations, environmental durability criteria (e.g., dust, moisture, impact resistance), communication protocols (e.g., ISO/IEC 18000-7 for active UWB or ISO/IEC 18000-63 for passive UHF), and integration interfaces with plant control systems. The DWG serves as an engineering baseline for procurement, installation, commissioning, and validation of RFID-based ore traceability infrastructure.
📖 Overview
📑 Key Components
🎯 Applications
- ✓ Real-time ore stream segregation for grade-based blending
- ✓ Automated reconciliation between mine production reports and mill feed assays
- ✓ Regulatory chain-of-custody documentation for export compliance
📐 Key Formulas
Tag Read Reliability Index (RRI)
RRI = (N_success / N_attempts) × 100%
Quantifies percentage of successful RFID reads per tag over a defined operational cycle; target ≥99.5% for critical tracking points.
Effective Read Range (d_max)
d_max = √(P_t × G_t × G_r × λ² × σ) / (4π × √(L_sys × SNR_min))